VICTORYSpray Foam
Builders & contractors

For builders and general contractors.

Our spec, the foam’s code reports, our paperwork and how we fit your schedule. Everything you need to put us on your job, on one page.

4.6 on Google · 58 reviews
  • Bids in 24 hoursFrom your drawings and specs
  • $1M / $2M insuredGeneral liability, certificate on request
  • Lifetime warrantyTransfers to the next owner
  • UPC MasterApplicator, veteran-owned
Why Victory

Why builders use us.

  • R-15 / R-22

    At 2 in and 3 in

    Closed cell puts real R-value into a thin wall. Figures for UPC 2.0 HFO.

  • Air barrier

    Not just insulation

    Open cell at 3¾ in or more, and closed cell at 2³⁄₁₆ in or more, are air-impermeable under the manufacturer's code reports.

  • Class II

    Vapor retarder

    Closed cell is a Class II vapor retarder at 1½ in.

  • Quieter

    Between units

    Open cell fills the whole cavity and dampens sound between rooms, floors and units.

  • Lifetime

    Transferable warranty

    Our foam is covered for the life of the building, and the warranty moves to the next owner.

  • UPC Master

    Applicator

    Manufacturer-trained on the foam we spray. Veteran-owned, based in Anderson.

The higher the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values.

Schedule

How we fit your schedule.

  1. Step 1Send the drawingsBids go back within 24 hours.
  2. Step 2Book 1–2 weeks outThat's the notice we need to get on your schedule.
  3. Step 3After electricalWe come in once electrical is done.
  4. Step 4We bring the liftsOur own lifts and scaffolding. The site needs driveway access for a 10-foot trailer.

We work across central Indiana, up to three hours out for larger projects, and into Michigan for the biggest commercial and farm jobs. Full service area

Spec

Our spec.

FoamWhere it goesTypical thicknessR-value at that thickness
Open cellAttic6 in +R-22
Closed cellAttic3 in +R-22
Open cellWalls3.5 in +R-13
Closed cellWalls2 in +R-15
Closed cellCrawlspace2 in +R-15
Closed cellRim joists2 in +R-15
Open cellPole barn, on OSB or liner4 in +R-15
Closed cellPole barn, on metal2 in +R-15

R-value measures how well insulation holds back heat. The higher the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values. R-values are for UPC 500 open cell and UPC 2.0 HFO closed cell, from the manufacturer's code compliance reports, at the thickness shown. Closed cell is rigid and also blocks moisture; open cell is softer and dampens sound. We choose the foam for each job. See the data sheets

Documents

Code reports and safety sheets.

Published by the manufacturer, Universal Polymers (UPC). The code reports cover thermal resistance, air and vapor permeance, fire testing, and thermal and ignition barriers.

All UPC data sheets

Paperwork

Paperwork and terms.

  • Insured: $1M / $2MGeneral liability, $1M per occurrence and $2M aggregate. We'll send a certificate made out to your company.
  • W-9 on requestAsk for it with your bid request.
  • Commercial termsDeposit and payment timeline agreed before work starts.
  • Veteran-ownedBased in Anderson, Indiana.
ENERGY STAR

Apartment buildings and ENERGY STAR.

0.30

CFM50 per square foot of enclosure: the most air each unit may leak

  • Air sealing is most of the checklistENERGY STAR Multifamily New Construction requires fully aligned air barriers, and a rater tests every unit.
  • We give your rater what they needThe foam's code reports and data sheets, plus the type and thickness we installed.
  • Ask your lender about green pricingSome multifamily loan programs offer better terms to certified buildings. Your lender can tell you which apply.

ENERGY STAR is a U.S. EPA program. ENERGY STAR does not endorse Victory Spray Foam.

Bid request

Send the project.

Attach drawings and specs, and we'll get a bid back to you within 24 hours. Need paperwork? Tick it below.

  • Bids within 24 hours
  • Certificate of insurance made out to you
  • W-9 on request
Drawings and specs
Paperwork you need